- How do I display the TMS curves on my TCC drawing? - SKM
Solution: Complete the following steps to display the TMS curves on the TCC drawing: Step 1 – In the TMS window, select the motor and current starting curve In the Case pull-down window, select ‘Save as TCC Starting Curve” Step 2 – Proceed to open the TCC drawing with the motor you want to display
- Power*Tools for Windows Tutorial - SKM
Time-Current-Coordination (TCC) drawings, Data Visualizer, and the Component Editor It is important to know how to navigate between the different Windows and Documents that may be open
- Relay Parameter amp; TCC Setting in SKM 3 - Eng-Tips
Open the library by clicking on the library icon ( 6th icon from the left ) Go CAPTOR > Relays > Electronic and select the relay VAMP 230 245 255 ( for ANSI 50 51 ) Click on the Trip Curves tab of the library dialog box The curve segment I>, (0 1-5 x PA) is for the Long Time Pickup segment which has a setting range of 0 1 to 5 x Primary Amps
- skm not showing all the TCC curves | Information by Electrical . . .
It took me a long time to find out that change the current multiplier( curve multiplier) from default 1 to 0 1 will show the curve But I don't want to do this for every single one of my TCC files Is there any global setting or automatically shift the curve way?
- How do I modify TCC curves that intersect other curves in CAPTOR? - SKM
Click on the Flag tab in the TCC Device – Setting Properties window Modify the Cut Off Current or Cut Off Time depending on the curve you wish to modify Repeat this for all the curves you want to change The final result shows both curves trimmed to be more visually appealing
- SKM Power*Tools ::: ELECTRICAL ENGINEERING SOFTWARE
The purpose of this guide is to provide basic information about transformer through-fault damage curves and characteristic landmarks necessary for plotting on time-current curves, for the purpose of equipment overcurrent protection
- Understanding time current curves: Part 1 - Control Engineering
The first installment of a three-part series about time current curves (TCCs) provides a quick overview of item identification and how to read TCC plots
- TCC Setting - Electric power transmission distribution - Eng-Tips
Right click on the TCC, select TCC Settings, then on the Layout Tab, change the number in Current Scale x 10^ With a 0, the 0 5A to 10,000A is just that; with a 1, the range becomes 5A to 100,000A; with a 2 the range becomes 50A to 1,000,000A Those should give you enough range to work with
- TCC Curves - Transformer Protection | Information by Electrical . . .
I am having a hard time trying to protect a transformer properly using SKM In the image below, the primary side protection (fuse "PD-0001") should be to the right of the inrush point at the bottom and then to the left of the primary side damage curve at the top
- SKM Software Help Desk - Knowledge base - CAPTOR (TCC)
How do I display the TMS curves on my TCC drawing? ↑↓ How do I modify TCC curves that intersect other curves in CAPTOR? ↑↓ How do I transfer devices between Captor libraries?
|
|